Aluminium facades HUECK
Trigon 50
Mullion / transom façade, 50 mm profile depth, same geometry for mullion and transom - 38
Construction:
- Thermally insulating aluminium facade design as a mullion-transom construction for vertical, slanting, level or polygonal curtain walls
- Identical profile geometry for mullion and transom
- Glass thickness between 4 and 58 mm
- Different insert elements from the HUECK system possible
Elevation width:
- Transom and cover profiles with an elevation width of 50 mm in various profile geometries
Profile depth:
- Depending on static requirements between 32 and 264 mm
Insulating zone:
- Insulating profiles made of glass fibre-reinforced polypropylene
- Foamed insulating profiles for increased thermal insulation
Gaskets:
- Shaped gasket pieces covering the entire joint area are used at the transom connection
- Optional single-piece or two-piece EPDM gaskets as external gasket
- Can be inserted on site without sealing material
Test results:
- Suitable for passive houses, ift guideline WA 15/2
- Water tightness static RE 1200, dynamic 250 Pa / 750 Pa (EN 12154)
- Air permeability class AE (EN 12152)
- Resistance to wind load 2.4 kN/m2 permitted load or 3.6 kN/m2 increased load (EN 12179)
- Bullet resistance up to FB 4-NS
- Burglar resistance WK 1 / WK2 / WK3 (ENV 1627)
Trigon 50 SG
Entirely glass aluminium façade construction, 50 mm profile depth - 4
Construction:
- All-glass facade construction with 22 mm silicone weather seal for vertical and inward inclined even or polygonal curtain walls
- European approval ETA 09/0335
- Maximum pane size 3000 mm x 5000 mm
- Easy and quick installation of the glass units
Elevation width:
- Transom and cover profiles with an elevation width of 50 mm
Profile depth:
- In accordance with static requirements between 32 and 194 mm
Insulating zone:
- Insulating profiles made of glass fi bre-reinforced polypropylene
- Foamed insulating profiles for increased thermal insulation
Gaskets:
- Vulcanised shaped gasket pieces covering the entire joint area are used in the transom connection area
Test results:
- Uf = 0.88 – 1.5 W/m2K
- Water tightness RE1200 (EN 12154)
- Air permeability 4A (EN 12152)
- Resistance to wind load 2400 / 3600 Pa (EN 13116)
- Impact strength I5 / E5 (EN 14 019)
- Sound reduction Rw,P up to 45 dB (EN ISO 140 - 3)
- Burglar resistance WK2, WK3 (ENV 1627)
- System test "Crash-safe glazing in accordance with TRAV"
- European approval ETA-13/0675